      當(dāng)前位置:首頁(yè)產(chǎn)品中心離心機(jī)臺(tái)式大容量離心機(jī)SG-852-type large-capacity centrifuge
      large-capacity centrifuge

      產(chǎn)品簡(jiǎn)介

      SG-852-type large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

      產(chǎn)品型號(hào):SG-852-type
      更新時(shí)間:2019-05-05
      廠商性質(zhì):生產(chǎn)廠家
      訪問(wèn)量:3434
      詳細(xì)介紹在線留言

      Product Introduction:
      SG-852-type large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
      Product features:
      1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
      2, simple: touch panel, digital display, intuitive and reliable;
      3, high-capacity multi-rotor, the user easily select
      Technical data:
      Maximum speed: 5000r/min
      1 rotor: 4 * 100ml
      No. 2 rotor: 8 * 50ml
      No. 3 rotor: 28 * 10ml
      Motor: Brushless DC Motor
      Timing range: 0-99min


      Handling Precautions
      Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
      1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
      2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
      3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees - 60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
      4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
      5. To ensure safety, be sure to use ground wire
      6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
      7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
      8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
      9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
       

      在線留言

      留言框

      • 產(chǎn)品:

      • 您的單位:

      • 您的姓名:

      • 聯(lián)系電話:

      • 常用郵箱:

      • 省份:

      • 詳細(xì)地址:

      • 補(bǔ)充說(shuō)明:

      • 驗(yàn)證碼:

        請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

      掃碼加微信,了解最新動(dòng)態(tài)

      掃碼加微信
      021-65682142

      Copyright © 2025 上海碩光電子科技有限公司版權(quán)所有

      技術(shù)支持:化工儀器網(wǎng)    sitemap.xml

      滬公網(wǎng)安備 31011002005640號(hào)

      主站蜘蛛池模板: 亚洲国产精品成人午夜在线观看 | 国产免费爽爽视频免费可以看| gdianav| 日本午夜精品一区二区三区电影 | 人人玩人人添人人| 天天爽夜夜爽人人爽一区二区 | 久久精品国产一区二区三区不卡| 激情欧美一区二区三区| 囯产精品一品二区三区| 欧美人与物videos另| 大学生美女毛片免费视频| 中日韩精品视频在线观看| 樱桃视频高清免费观看在线播放| 亚洲色大成网站www永久| 老公和他朋友一块上我可以吗| 国产欧美va欧美va香蕉在| 97午夜理伦片在线影院| 性生活片免费看| 久久亚洲欧美日本精品| 欧美乱大交xxxx| 亚洲精品无码mv在线观看网站| 精品视频一区二区三三区四区| 国产在线精品一区二区夜色| 你懂的国产高清在线播放视频| 大胸年轻继拇3在线观看| 中文国产成人精品少久久| 日韩人妻高清精品专区| 亚洲国产日韩欧美一区二区三区 | 香蕉伊思人在线精品| 夜夜偷天天爽夜夜爱| 一级特黄录像免费播放中文版 | 884hutv四虎永久7777| 在线精品91青草国产在线观看| 一道本免费视频| 日产精品久久久久久久| 二代妖精在线观看免费观看| 欧美日韩你懂的| 亚洲色av性色在线观无码| 精品一区二区三区波多野结衣| 国产AV国片精品一区二区| 香蕉在线精品视频在线观看2|